Browse all practice questions for the Colorado Journeyman Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Colorado Journeyman Practice Exam 2026 – The All-in-One Guide to Master Your Exam and Certification! course image
All questions

These questions are part of the practice quiz. Start practicing

  • In Colorado, what is the code enforcement body for electrical work?
  • What is the maximum number of disconnecting means required for a 240/120-volt three-wire feeder installed underground from a dwelling to a detached garage?
  • Given a transformer with a primary rating of 1000 volts and rated primary amperage of 5 amps, the overcurrent protection device rating shall not exceed __________?
  • Transformers and transformer vaults shall be __________ to qualified personnel for inspection and maintenance.
  • What does the acronym "NEC" stand for?
  • What type of wiring is commonly used in residential electrical systems in Colorado?
  • What must be provided between conductors and armor in armored cable installation?
  • When passing over roofs, coaxial cables shall have at least __________ ft of clearance from all points on the roof.
  • What is the minimum ampacity required to supply a 12.0 kW electric furnace with a 1/3-HP motor at 240 volts?
  • What is a legal requirement for repairing an electrical code violation in Colorado?
  • Which cable type is permitted to be used as a substitute for BLX?
  • What type of insulation is required for conductors located in a damp environment?
  • What is the minimum size of the service entrance conductors for a dwelling unit with five 2-wire branch circuits?
  • What is the term for the conductive paths that provide a ground-fault current path in electrical equipment?
  • What should be considered when choosing fuses for motor circuits?
  • What is a common installation practice for mounting electrical panels?
  • How is "voltage" defined?
  • What is the proper method for splicing two conductors together?
  • How many No. 4/0 THW copper conductors may be installed in a 2-1/2-inch EMT conduit nipple six inches long installed between a panel and a wireway?
  • What device is used to prevent overcurrent in electrical circuits?
  • What is the maximum interval at which Liquidtight Flexible Metal Conduit must be supported?
  • What is the acceptable temperature range for residential wiring in Colorado?
  • When calculating demand loads for a dwelling unit, which types of loads must be considered?
  • Which component is essential for providing safety in wet locations when referring to electrical installations?
  • What adjustment factor is applied to 4 pieces of 12/2 MC cable supplying 240-volt single-phase loads?
  • Sills or curbs in transformer vaults, shall have a minimum height of __________.
  • What percentage of ampacity must be applied to conductors when housed together in a raceway?
  • What are feeder conductors used for?
  • Class 2 and Class 3 remote control and signaling circuit wiring shall not be secured to what?
  • Which of the following is not a purpose of electrical codes?
  • What is the maximum secondary circuit voltage for sign transformers?
  • What is the minimum age requirement to take the Colorado Journeyman Exam?
  • How far must an outlet for laundry equipment be installed from the intended location of the appliance?
  • What is the maximum number of 15- and 20-ampere receptacles permitted in a single circuit?
  • What type of circuit protects against short circuits and overloads?
  • In an electrical circuit, what does GFCI stand for?
  • What type of circuit wiring cannot be run through raceways according to the NEC?
  • "Connected to the ground or to a conductive body that extends the ground connection." refers to which term?
  • What is the minimum ampacity required for branch-circuit conductors for a 115-volt, 3 HP motor with a nameplate current rating of 36.5 amperes?
  • What is the primary function of a junction box in electrical systems?
  • What is the maximum permitted cord- and plug-connected load to a 15-ampere receptacle?
  • What is the preferred method for grounding a service in Colorado?
  • What is the maximum time-delay fuse permitted for a No. 1 AWG copper THHN motor feeder for five 480-volt, 3-phase induction motors?
  • Which of the following uses is not acceptable for flexible cords?
  • What is the primary purpose of AFCI protection in residential circuits?
  • A mobile home park with 26 mobile homes having a computed load of 22,000 volt-amperes requires service conductors with what ampacity?
  • What is the purpose of using multi-wire branch circuits?
  • What is the minimum distance for nonmetallic-sheathed cable from the edge of a scuttle hole in an attic?
  • What section of the NEC specifies the requirements for temporary wiring?
  • Which article of the NEC pertains to hazardous locations?
  • What is the minimum number of receptacles required for a 6-foot wide kitchen counter top?
  • What is the definition of electronic computer processing equipment?
  • What is a major benefit of having service entrance cables rated for wet locations?
  • What is the feeder demand load for four 14kW residential ranges?
  • Which section of the NEC deals with swimming pool installations?
  • What is the primary insulation rating required for conductors in damp locations?
  • What is a feeder in electrical systems?
  • Which of the following best describes the purpose of an electrical transformer?
  • What is a branch circuit with two or more un-grounded conductors called when it has equal voltage to a grounded conductor?
  • How many outdoor receptacles are required at a dwelling unit?
  • Code requirements state that the disconnecting means for a circuit providing power to a pump for an LP-Gas filling station must include which of the following?
  • Which part of the Colorado Administrative Code contains the laws regulating electrical installation?
  • A __________ shall be installed where cables emerge from raceway used for mechanical support or protection in accordance with code guidelines.
  • Which of the following is not required to be bonded on a hot tub installation?
  • What is the maximum riser length allowed for a service drop in residential installations?
  • Which color indicates a ground wire in residential wiring?
  • Which type of circuit breaker is used to protect the primary side of a transformer with a secondary connected to industrial equipment?
  • How close to the nearest edge can NMC be installed when parallel to framing members?
  • The definition of a forming shell as used in a swimming pool is best described as which of the following?
  • Which code revision year is commonly used as a reference for current electrical installations?
  • The listed exposed work cover is permitted to serve as the grounding and bonding means when mounted correctly. What is required for this?
  • What is the maximum number of No. 14 AWG THHN copper conductors allowed in 3/8-inch flexible metal conduit using external clamp-type fittings?
  • What is the voltage drop for a three-phase, 3-wire, 240-volt circuit with a load of 5 HP located 110 ft away from the panel using No. 8 AWG copper THHN?
  • What is the purpose of the Colorado Electrical Board?
  • What is the primary code book used for the Colorado Journeyman Exam?
  • What feature must dry-type transformers have when installed outdoors?
  • The conductive path installed to connect normally non-current carrying metal parts of equipment to the grounded conductor is called the ___________?
  • What is the term used for notes that provide additional information but are not mandatory?
  • What is the minimum height for outdoor service conductors to ensure safety?
  • What is the primary material used for electrical service conductors in Colorado?
  • "The greatest root-mean-square difference of potential between any two conductors of the circuit concerned" is known as what?
  • How many grounding electrodes are required for a residential service system?
  • Which term defines "a unit of an electrical system that carries or controls electric energy as its principal function"?
  • How much change in length would 100 ft of PVC conduit experience with temperature fluctuations from -10°F to 110°F?
  • What type of conduit should a feeder from a dwelling unit to a detached garage be installed in?
  • Under what circumstance can an electrical panel be mounted higher than 6.5 feet above the ground?
  • What is the minimum size required for secondary conductors if a transformer has no secondary conductor protection?
  • Each patient location in a health care facility shall be supplied by at least __________ branch circuits.
  • A device that connects bonding conductors for communication systems to the grounding electrode system is known as _____________.
  • In Colorado, what is the estimated penalty for performing electrical work without a license?
  • Which of the following is a common cause of electrical fires?
  • Which section of the NEC addresses outdoor and special-purpose installations?
  • What is a common method to calculate load for a dwelling unit?
  • What is the minimum size THWN aluminum service conductor permitted by Code to supply a 400-ampere, 120/240-volt service to a single family dwelling?
  • What is the primary function of a GFCI protected receptacle?
  • What is the largest circuit breaker allowed to protect a 25 HP three-phase, 480-volt induction motor?
  • Which type of cable is permitted to be used as a substitute for OFCR?
  • What is the minimum height for a service drop above a residential driveway?
  • In a 1,600 sq. ft. dwelling unit with 74 receptacle outlets, what is the calculated feeder load for lighting and other loads?
  • Each kitchen is required to have a minimum of how many small appliance branch circuits?
  • Which of the following built-in appliances can be connected using a cord and plug in a dwelling?
  • What device is required to protect circuits that are installed in locations prone to moisture?
  • What type of receptacles must be installed in areas where electrical diagnostic equipment or portable lighting is used?
  • What is the minimum height above finished grade for receptacles located outside?
  • For a single-phase motor fed from an underground source, where should the motor overload unit be placed?
  • What is the definition of a "lighting outlet" in NEC terms?
  • The overcurrent protection device on the primary side of a transformer operating at less than 1000 volts must be set at no more than __________ percent of the transformer’s rated primary current?
  • What type of fault is mainly prevented by the use of GFCI devices?
  • How are circuit conductors identified according to the NEC?
  • According to code, how many telephone outlets are required for new dwellings?
  • In residential installations, which type of conductor is typically used for short runs in walls?
  • What term is used for mandatory rules in the NEC characterized by the use of the word "shall"?
  • What is the allowable ampacity for a 30 AWG conductor used as part of the control wiring in a permanent amusement attraction?
  • How often must electrical installations in commercial buildings be inspected?
  • What is the primary purpose of grounding in electrical systems?
  • What is the minimum ampacity permitted for the feeder supplying a group of single-phase squirrel-cage induction motors totaling 32.5 HP?
  • How often is the National Electrical Code updated?
  • In regards to freestanding receptacles, which of the following is true?
  • According to electrical codes, how far from a scuttle hole should nonmetallic cable be placed unless protected by guard strips?
  • What is the primary purpose of a circuit breaker?
  • What constitutes a violation when installing receptacles in a residential dwelling?
  • A ground rod must be a minimum of how many feet in length?
  • Which type of circuit breaker is designed to protect against ground faults?
  • What is the recommended accepted standard for branch circuit protection of electric motors?
  • Which section of the NEC covers the general requirements for electrical installations?
  • What is one key factor when determining the ampacity of a motor circuit?
  • What is the purpose of a service lateral?
  • Which Code article specifies the minimum requirements for service conductors feeding a 400-ampere service?
  • What is the minimum voltage for low voltage lighting systems?
  • Which of the following components provides a protective measure by interrupting the flow of electricity in case of a ground fault?
  • What safety test must GFCI outlets pass before installation?
  • What is the minimum wire size for a bonding bar connected to the equipment grounding conductors in the service equipment enclosure?
  • The total square inch area of a three-inch intermediate metal conduit is __________.
  • What is the minimum height for installing a residential service entrance?
  • What is the maximum number of outlets allowed on a 15-amp circuit in a residential setting?
  • What is a common application for OFCP cable?
  • What determines the number of branch circuits required for a residential structure?
  • In regards to flexible cords, which situation is permissible?
  • Which of the following cannot be used as a grounding electrode?
  • What is the minimum size copper wire allowed for residential branch circuits in Colorado?
  • For a 10kVA single-phase transformer with a 30 amp circuit breaker on the primary, what is the minimum size allowed for secondary conductors?
  • Which of the following is typically required for outdoor wiring installations?
  • What is the allowable voltage drop for branch circuits according to the NEC?
  • Which circuit component is crucial for protecting against voltage spikes?
  • Which of the following describes the Code requirements for a 125-volt, 20-ampere outdoor receptacle in a bathroom?
  • What kind of protection is required between conductors and armor in armored cable?
  • What is a significant benefit of using AFCI breakers in residential settings?
  • Are sign transformers covered by Article 450?
  • What does the term "ampacity" refer to?
  • What is the function of a ground fault circuit interrupter (GFCI)?
  • What is the minimum size aluminum equipment-grounding conductor required for a feeder of four three-phase motors?
  • What Code requirement applies to a wall receptacle installed within 6 feet of a wet bar in a family room?
  • What designation is used for overhead power lines that are less than 600 volts?
  • Remote-control circuits to safety-control equipment classified as Class __________ involve a direct fire or life hazard.
  • What is the common term for a circuit that uses both 120V and 240V?
  • What is the code section that specifies requirements for working safely near overhead power lines?
  • Which of the following equipment does Article 430 primarily apply to?
  • For a grounded 400-ampere AC system, what is the minimum wire size permitted for the grounding-electrode conductor connected to a rod or pipe electrode?
  • What percentage of campsites in a new recreational vehicle park must have a 50-ampere 120/240-volt supply installed?
  • In one- or two-family dwellings, what is the maximum length for the primary protector bonding conductor or grounding electrode conductor?
  • For residential electrical systems, what is the required minimum number of circuits in the kitchen?
  • A listed package spa assembly with a factory-installed ground-fault circuit-interrupter is connected indoors to a wall receptacle. What is required for compliance?
  • To what maximum percentage can splices and taps fill a surface nonmetallic raceway?
  • According to NEC code, how many receptacles are allowed in a kitchen area for small appliances?
  • What does the color black typically represent in residential electrical wiring?
  • In a 120/240-volt, single-phase, 200-ampere service, what is required for the main bonding jumper connection to the service equipment enclosure?
  • What tool is commonly used to measure electrical current?
  • What is the operating maximum voltage for a typical residential electrical system in Colorado?
  • What is the required insulation temperature rating for branch-circuit conductors near a ballast?
  • Which of the following is not an approved fixed wiring method for a place of assembly?
  • What is required for all electrical installations in terms of accessibility?
  • What is called the "electric power production and distribution network"?
  • How long must electrical records be retained according to Colorado regulations?
  • If a raceway is installed in a wet location above grade, how is its interior classified?
  • What is the allowable ampacity reduction percentage for raceways with 10 current-carrying conductors according to standard guidelines?
  • What determines the lifting load limit for existing structures when installing new electrical services?
  • For motors rated at over 10 HP, which standard must be referred to for necessary protection?
  • What do you call the electrical system grounding point created by a common ground?
  • What type of receptacle is required in outdoor locations according to the electrical code?
  • What must replace a two-wire receptacle in a bathroom when no grounding conductor is available?
  • What is the primary function of a device in an electrical system?
  • A multiwire branch circuit must have a means to disconnect all un-grounded conductors in what manner?
  • What is the primary purpose of using conduit in electrical installations?
  • What is the function of a disconnect switch in an electrical system?
  • A "park trailer" is defined as having a gross trailer area not exceeding __________ sq. ft. in set up mode.
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy